The manufacture of bespoke channel letters combines a face, sides, a back and, for a lit version, front LED lighting or halo/backlighting. Each element contributes to the appearance and to installation preparation.
Explore assembled, exploded and cutaway views. For illuminated models only, LEDs & power supply shows the modules and wiring. This control is disabled for non-illuminated versions. Manufacturing specifications are defined for each project.
Day version
Night version
KAPELLA / 3D CONSTRUCTIONBox letter · illuminated faceNight · Illuminated areas: front face. Assembled view: outer volumeH / height · D / depth · t / thicknessesEdge thickness = depth. Manufacturing dimensions to be confirmed on the proof.PRINCIPE DE CONSTRUCTION · FABRICATION SELON BAT VALIDÉ · NO SCALEKAPELLA · SIGNS FOR PROFESSIONALSkapellamedia.comCustom sign manufacturing · Europe & United KingdomKAPELLA TECHNICAL DOCUMENTConstruction principleCharacteristics to be confirmed for the projectKAPELLA / 3D CONSTRUCTIONBox letter · illuminated faceExploded view: separate parts on their assembly axes+ / − to the LED modulesPower supply entryIndicative layoutLED01Mounting support02Fixings / stand-offs03Back panel / base plate04LED modules05Recessed sides06Removable diffusing face07LED power supply / transformer08LED connections (+ / −)Technical sheet: channel letters | Kapella01Technical sheet: channel letters | Kapella02Technical sheet: channel letters | Kapella03Technical sheet: channel letters | Kapella04Technical sheet: channel letters | Kapella05Technical sheet: channel letters | Kapella06Technical sheet: channel letters | Kapella07Technical sheet: channel letters | Kapella08H / height · D / depth · t / thicknessesEdge thickness = depth. Manufacturing dimensions to be confirmed on the proof.PRINCIPE DE CONSTRUCTION · FABRICATION SELON BAT VALIDÉ · NO SCALEKAPELLA · SIGNS FOR PROFESSIONALSkapellamedia.comCustom sign manufacturing · Europe & United KingdomKAPELLA TECHNICAL DOCUMENTConstruction principleCharacteristics to be confirmed for the projectKAPELLA / 3D CONSTRUCTIONBox letter · illuminated faceOpen view: faces removed to read the internal components+ / − to the LED modulesPower supply entryIndicative layoutLEDH / height · D / depth · t / thicknessesEdge thickness = depth. Manufacturing dimensions to be confirmed on the proof.PRINCIPE DE CONSTRUCTION · FABRICATION SELON BAT VALIDÉ · NO SCALEKAPELLA · SIGNS FOR PROFESSIONALSkapellamedia.comCustom sign manufacturing · Europe & United KingdomKAPELLA TECHNICAL DOCUMENTConstruction principleCharacteristics to be confirmed for the projectKAPELLA / 3D CONSTRUCTIONBox letter · halo/backlightingExploded view: separate parts on their assembly axes+ / − to the LED modulesPower supply entryIndicative layoutLED01Mounting support02Fixings / stand-offs03Diffusing rear back panel04LED modules05Recessed sides06Removable opaque face07LED power supply / transformer08LED connections (+ / −)Technical sheet: channel letters | Kapella01Technical sheet: channel letters | Kapella02Technical sheet: channel letters | Kapella03Technical sheet: channel letters | Kapella04Technical sheet: channel letters | Kapella05Technical sheet: channel letters | Kapella06Technical sheet: channel letters | Kapella07Technical sheet: channel letters | Kapella08H / height · D / depth · t / thicknessesEdge thickness = depth. Manufacturing dimensions to be confirmed on the proof.PRINCIPE DE CONSTRUCTION · FABRICATION SELON BAT VALIDÉ · NO SCALEKAPELLA · SIGNS FOR PROFESSIONALSkapellamedia.comCustom sign manufacturing · Europe & United KingdomKAPELLA TECHNICAL DOCUMENTConstruction principleCharacteristics to be confirmed for the project
Description and characteristics to be specified
Reference / component
Function and characteristics
01 / Installation support
Façade to be identified: type, condition, insulation, rear access and openings. Installation is studied on the actual support.
02 / Fixings / stand-offs
Mechanical example. Number, offset, diameter and anchor points are to be defined according to the substrate.
03 / Base / foot
It carries the LEDs and closes the back. Material and thickness to be specified.
04 / LED modules
Modules on the base. Distribution according to the layout and depth; voltage, colour and power to be specified.
05 / Hollow edges
Sides in folded, powder-coated aluminium sheet, 1.5 mm thick. Depth and assembly depend on the project.
06 / Removable diffusing face
3 mm light-diffusing PMMA face, with no visible trim. Internal retention and maintenance access to be specified.
07 / LED power supply / transformer
Power supply positioned behind the letter, within its outline. Access, protection, ventilation and rear housing depend on the mounting arrangement.
08 / LED connections (+ / −)
The routing of the two conductors follows the modules. The connections are shown for the purpose of understanding the principle; sections, protection and connections are defined in the technical file.
The exploded view separates the face to show the hollow volume, the LEDs and the electrical routing. Finish without visible edging; the face is held in place by an internal system to be defined.
Composition and options to be specified
Face
Opaque or diffusing depending on the lighting method. Material and colour to be defined.
Sides
Material, depth, appearance and colour to be specified according to the visual.
Back
Construction and cable routes to be planned according to the mounting.
Lighting
Front-lit, halo/backlit or combined: the construction must match the required finish.
Fixings
Direct installation, stand-offs or intermediate support to be assessed according to the façade.
Finish
RAL reference or other colour, matt, satin, gloss or metallic finish depending on the material.
File to be submitted
Vector logo and text
Overall dimensions and letter height
Façade photos
Desired light output and finish
Help document for preparation. The dimensions, materials, electrical characteristics, fixings, prices and applicable lead times are those of the validated quotation for the project.